15
PL-250HT / PL-350HT / PL-500HS
systems charging
procedure, systems 2011 to present (single LED
charger)
t Connect the charger and battery by inserting the
charge connector into the charge port. The BionX
system should be turned off
t Connect the charger to a power receptacle
t The light on the charger will turn red automatically
t The same light will then turn yellow to indicate
charging
t The light will turn green when the battery is fully
charged and the charging process is complete
t Following this procedure, the charger should be
disconnected from the battery
PL systems 22V, 26V, 37V charging procedure,
systems 2011 and earlier (two LED charger)
t Connect the charger and battery by inserting the
charge connector into the charge port. The BionX
system should be turned off
t Connect the charger to a power receptacle
t The power switch must be set to ‘on’ and the red
LED will illuminate
t The LED to the right of the red LED will illuminate
yellow to indicate charging
t When the right LED turns green the battery is fully
charged and the charging process is complete
t Following this procedure, the charger should be
disconnected from the battery
WARNING
Check input voltage when travelling with
the two LED charger. Failure to adjust the
voltage switch on a two LED charger to
the correct voltage range can result in
damage to the charger.